Home
About Us
Recent Projects
Mining Subsidence
Tell A Friend
Contact Us
Our Services
Roofing
Health & Safety
Environment Policy
Employment Opportunities.
Links

Recent Projects.

New Roof (January 22, 2009)
This project is to strip off all existing slates to roof due to nail rot.
Fit new underlay felt and existing slates.
 
oak609
 
 
Below is a photograph of the existing roof which you can see slates are starting to slip, this due to the nails rotting.
 
These existing welsh slates are still in perfect condtion and we beleive will out last any new type of slate which is on sale today.
 
In view of above and to keep costs down, our client has decided to re-use these existing slates.
 
 
oak612

  

  
 
  
All slates and laths have now been stripped.
The Building Inspector for the local council has inspected the esiting roof struture and now confirms that they fine.
  
FACT:  All roof renewals require a Building Notice service into the Council.
Without a building notice your local council can enforce action for the works to be re-done.
ALLWAYS MAKE SURE THAT A BUILDING NOTICE IS SERVED.!
IF IN DOUBT, CHECK WITH YOUR COUNCILS BUILDING CONTROL DEPARTMENT.
  
oak627
  


Our operatives carefully removes the existing slates for re-use.

oak971

oak975

All slates and old laths have now been removed.
New laths and felt being fitted.

Take Note:
As you can see, we are fitting what we believe is the best Fully Breathable underlay felt which is on the market today (Tyvek), which unfortunately is the most expensive.
We also provide a 10mm overfascia vent to provide the correct airflow of which is needed for this underlay to breath correctly.  Also eave protectors are always fitted which again is a requirement so that the underlay felt does not rot inside the gutters.

FACT:.
A lot of roofers will NOT fit the eave protectors.
Will NOT fit over fascia vents.
Any will NOT fit Tyvek, but a must cheaper alternative which will not be approved by your local council.
Therefore your roof will not breath correctly which could have a devastating long term effect.

When you ask a company for a quotation,demand that they include the above materials in their quotation.

Ask you local council, Building Control to verify the above material requirements.


oak986

oak1004

oak986

Whilst renewing the roof it was noticed that the brickwork gable was in poor repair.  We have therefore removed the danger and intend on rebuilding re-using the existing bricks.

oak1030

oak1102

Whilst renewing the rear roof we noticed that the dormer was in poor state of repair.  We totally stripped out the existing dormer window and roof and rebuilt.

oak1103

Brickwork being rebuilt.

oak1104

oak1105

Gable full repointed and peak rebuilt.

oak1179

Project is now full completed.

oak1181

oak1185

oak1175

This project is now complete.

Click here to return to the Recent Projects page